Installation precautions of air classifier
1. Perform a preliminary inspection of the classifier, fan and other host equipment. Whether there is any damage to the components during transportation or after long-term storage, check whether there is any foreign matter in the internal cavity of the equipment and the air duct of the fan, rotate the grading impeller and the main shaft of the fan, and observe whether Flexible rotation.
2. Check the tightness of the pre-installed parts of the equipment, and add lubricating oil to the parts that need to be lubricated.
3. Install the grading wheel to prevent collision. The grading main engine and fan should be level tested, and the level should be found with gaskets, and those with basic requirements should be fixed with the foundation.
4. Sealing gaskets should be equipped for the pipeline interfaces that require sealing.
5. After the classifier is installed, observe the running direction of the classifying motor first.
6. When installing and wiring the electric control cabinet, carefully check the corresponding relationship between the serial number of the wiring terminal and the equipment, and it should not be misplaced.
7. After installation, you can run the vehicle empty for 1-2 hours, tighten the loose bolts at any time, and carefully check the accuracy and coordination of the equipment actions.